STANDARD FEATURES
|
|
|
|
Hydraulic Switching
|
|
The pump operates entirely on a hydraulically
actuated system. This hydraulic system has
been proven on thousands of pumps operating
daily that are conveying a multitude of
materials under widely varying operating
conditions. The pumps do not rely on proximity
switches or other electrical devices for
proper operation. As most pumps operate
under harsh conditions, subject to wash
down, exposure to pumped media, natural
elements, or accidental blows by Operators
or Mechanics, the reliability of proximity
switches does not meet Schwings high
standards for equipment availability rates.
|
|
|
|
|
|
Water Box Safety Switch
|
|
When servicing the material rams from the
local control panel stationed near the water
box, the local panel is set up such that
a Mechanic or Operator must use two hands
to actuate the material cylinders, thus
ensuring the Technicians hands are free
and clear of any danger.
|
|
|
|
|
|
Hardened Poppets
|
|
The Poppet wearing components (discs and
seats) are made of steel, case hardened
to Rc 55, for a long and reliable service
life.
|
|
|
|
|
|
Hydraulic Power Pack
|
|
Each pump is delivered with its own hydraulic
power pack. Each power pack is sized and
designed to meet the requirements of the
specific application: pressure, flow, cooling,
allowable dB levels, dimensional and weight
requirements, etc.
|
|
|
|
|
|
Control Panel
|
|
Schwing supplies a control package utilizing
the Customers preferred PLC and networking
platform. Control panels may include, per
Customers request, HMIs, motor starters,
and other devices as required. Control panels
are pre-wired to the hydraulic power pack
unless a separate wall-mounted or freestanding
unit is requested. Panels may be constructed
to NEMA or IP standards as required.
|
|
|
|
|
|
Other Standard Features:
|
|
Hard chrome plated pumping cylinders.
25 mm water supply and overflow connections
to pump water-box.
Emergency-stop push button located
near pump water box.
|
|
|
|
|