OPTIONAL FEATURES
|
|
|
|
Sludge Flow Measuring System (SFMS)
|
|
Schwings patented flow measuring
system operates on the principle of variable
calculated filling efficiencies for each
individual pumping stroke. As such the SFMS
measures the volume of material pumped to
within +/- 5%.
|
|
|
|
|
|
Dual Discharge
|
|
The pump may be equipped with a dual discharge.
This shall allow the unit to simultaneously
pump to two separate grout injection points.
|
|
|
|
|
|
Pressure Compensating
|
|
The pump may be equipped with pressure
sensors in the material pipeline to prevent
over-pressurization of the tunnel annulus.
As the pressure in the line reaches a certain
pre-determined level, the pump can be programmed
to either decrease its output, or shut down.
|
|
|
|
|
|
Casters
|
|
The pump frame may be equipped with casters,
complete with jacking screws, to afford
the ability to roll the pump away from other
equipment to either perform maintenance
on the pump, or the neighboring equipment.
|
|
|
|
|
|
Air Oil Cooler
|
|
The oil-conditioning unit that is standard
on the hydraulic power packs is a Water
Cooler. Optionally, when project sites are
remotely located and water-cooling is not
an option, the power packs may be equipped
with Air Coolers.
|
|
|
|
|
|
Closed Loop Controls
|
|
Schwing can supply level and pressure sensors
and the required programming logic to offer
a "Closed Loop" control package
that integrates the material handling system
surrounding the Schwing supplied equipment.
|
|
|